Resource requirements and performance depend on the super sampling rate selection (NUM_PHASES). They also depend on the mode of operation: 32-terms (single grid) or 64-terms (double grid). The resource numbers are also susceptible to the version of implementation tools used. The following table provides the latest resource utilization and maximum clock frequency values.
| Configuration | Resources | FMAX | |||||
|---|---|---|---|---|---|---|---|
| Number of Phases | 32/64 Terms | LUT Access on AXI4-Stream | FFs | LUTs | DFE_NL_FIRs | -2LI (MHz) | -2LVI (MHz) |
| 1 | 32 | 0 | 807 | 371 | 1 | 491.52 | 491.52 |
| 2 | 32 | 0 | 943 | 411 | 1 | 491.52 | 491.52 |
| 3 | 32 | 0 | 1657 | 825 | 2 | 491.52 | 491.52 |
| 4 | 32 | 0 | 1914 | 844 | 2 | 491.52 | 491.52 |
| 1 | 32 | 1 | 750 | 296 | 1 | 491.52 | 491.52 |
| 2 | 32 | 1 | 886 | 336 | 1 | 491.52 | 491.52 |
| 3 | 32 | 1 | 1557 | 654 | 2 | 491.52 | 491.52 |
| 4 | 32 | 1 | 1814 | 677 | 2 | 491.52 | 491.52 |
| 1 | 64 | 0 | 1340 | 792 | 2 | 491.52 | 491.52 |
| 2 | 64 | 0 | 1761 | 1149 | 2 | 491.52 | 491.52 |
| 1 | 64 | 1 | 1240 | 620 | 2 | 491.52 | 491.52 |
| 2 | 64 | 1 | 1661 | 977 | 2 | 491.52 | 491.52 |