Follow these steps to read LUT data
from the target location through the AXI4-Stream interface:
- Add/assign target NL unit (
unit_sel), target LUT (lut_sel), target location (addr) tos_axis_lut_config_tdataas mentioned in thes_axis_lut_config_tdataformat. - Set the write (wr) bit Low to indicate that the transaction is a read transaction. You can assign zeros to write data (wdata) here.
- Form
s_axis_lut_config_tuserwith target NLF block (nlf_sel) as mentioned in thes_axis_lut_config_tuserformat. - Assert the
s_axis_lut_config_tvalidsignal. - Repeat steps 1 to 4 to read other target locations.
Note: The LUT data is available on
m_axis_lut after some latency. The latency varies based on the core
configuration but it is faster than AXI4-Lite
interface. You can read LUT values continuously on every clock cycle.
m_axis_lut_tdata is a 32-bit complex LUT
value. The 16 LSBs contain the signed real value and the 16 MSBs contain the signed
imaginary value.
The following figure illustrates the timing for LUT access through AXI4-Stream.
Figure 1. LUT Data Access through AXI4-Stream Channel