There are two files where you can modify the parameter values to get the desired configurations for the test cases.
- nlf_default_config.m
- Contains default configuration.
- set_test_case_params.m
- Used to set the test case parameters for each test case.
If both nlf_default_config.m and set_test_case_params.m define the same parameter, the parameter uses the value assigned in set_test_case_params.m.
Test case parameters are entered through a user-friendly MATLAB script set_test_case_params.m which has a top-level structure defined as xdfenlf_cosim_params.tc(tc_num).<xdfenlf_param>.
The xdfenlf_cosim_params is the main
structure while tc(tc_num) is the nested structure for
each test case containing the parameter set corresponding to the test case number
tc_num. xdfenlf_param is the DFE NLF parameter or test parameter for the test
case.