To support independent reference clocks for TX and RX with independent rate control of all SDI links, a separate PLL is required for each simplex, that is, two PLLs for each SDI link. Because there are only two PLLs in a DUO, one link per DUO or two links in a QUAD can be supported.
However, four links can be supported, provided that all 4xRX links run only integer (at different rates) using the rate grouping feature in the GT Wizard. For example:
- Link 1 RX can be at 1.5G integer
- Link 2 RX can be at 3G integer
- Link 3 RX can be at 6G integer
- Link 4 RX can be at 12G integer
Nevertheless, for the same example, two links cannot be at integer and fractional.
You can select the Rate Grouping option in the GT Bridge as shown in the following figure.
In this case, to support four links with independent reference clocks, you cannot run a link in RX in integer and another link of RX in fractional rate. Refer to the following example for supported and non-supported cases.
- Supported case
-
- Rx0 can be at 12G Integer
- Rx1 can be at 6G Integer
- Rx2 can be at 3G Integer
- Rx3 can be at 1.5G Integer
- Supported case
-
- Rx0 can be at 12G Fractional
- Rx1 can be at 6G Fractional
- Rx2 can be at 3G Fractional
- Rx3 can be at 1.5G Fractional
- Non-supported case
-
- Rx0 can be at 12G Integer
- Rx1 can be at 6G Fractional
- Rx2 can be at 3G Integer
- Rx3 can be at 1.5G Fractional