tx_change_fail_code Output Port Encoding - 2.2 English

UHD-SDI GT LogiCORE IP Product Guide (PG380)

Document ID
PG380
Release Date
2024-11-18
Version
2.2 English

The following table describes tx_change_fail_code output port encoding:

Table 1. tx_change_fail_code Output Port Encoding
Code Description
0 Reserved
1 When a change of the TX SDI mode is requested that requires changing the TXDATA_WIDTH attribute in the GT transceiver, the UHD-SDI control module attempts to do a DRP write cycle to change that attribute. If the UHD-SDI DRP control module detected a mismatch between the written TXDATA_WIDTH value and its actual content after retries, the sequence fails with this failure code.
2 When a change of the TX SDI mode is requested that requires changing the TXINTDATA_WIDTH attribute in the GT transceiver, the UHD-SDI control module attempts to do a DRP write cycle to change that attribute. If the UHD-SDI DRP control module detected a mismatch between the written TXINTDATA_WIDTH value and its actual content after retries, the sequence fails with this failure code.
3 When a change of the TX SDI mode is requested that requires changing the TXOUT_DIV attribute in the GT transceiver, the UHD-SDI control module attempts to do a DRP write cycle to change that attribute. If the UHD-SDI DRP control module detected a mismatch between the written TXOUT_DIV value and its actual content after retries, the sequence fails with this failure code.
4 The gtwiz_reset_tx_datapath_in port of the GT Wizard IP is asserted after completing a series for DRP and GT port during a dynamic change to reset the GT TX portion. If the gtwiz_reset_tx_done_out port of GT Wizard IP failed to assert after retries, the sequence fails with this failure code.
7-5 Reserved