Read and write address channels are served with equal priority in this mode. Although the name suggests reads have priority over writes, in actuality reads do not have priority. The requests from the write address channel are processed when one of the following occurs:
- No pending requests from read address channel.
- Read starve limit of 256 is reached. It is only checked at the end of the burst. When the controller is not able to execute/process the reads for 256 cycles, then go ahead and execute writes.
- Read wait limit of 16 is reached. AXI shim is neither accepting the read commands from AXI master nor sending read commands to the memory controller for 16 cycles.
The requests from the read address channel are processed in a similar method.