When the master bridge receives a read request with the Length = 0x1, FirstBE = 0x00, and
LastBE = 0x00, it responds by sending a completion
with Status = Successful Completion.
When the master bridge receives a write request with the Length =
0x1, FirstBE = 0x00, and LastBE = 0x00 there is no
effect.
| Transfer Type | Abnormal Condition | Bridge Response |
|---|---|---|
| Read | DECERR response |
MDE interrupt strobe asserted. Completion returned with Unsupported Request status. |
| Write | DECERR response | MDE interrupt strobe asserted. |
| Read | SLVERR response |
MSE interrupt strobe asserted. Completion returned with Completer Abort status. |
| Write | SLVERR response | MSE interrupt strobe asserted. |
| Write | Poison bit set in request |
MEP interrupt strobe asserted. Data is discarded. |
| Read | DECERR response |
MDE interrupt strobe asserted. Completion returned with Unsupported Request status. |
| Write | DECERR response | MDE interrupt strobe asserted. |