Clocking - Clocking - 3.4 English - PG346

Versal Adaptive SoC CPM Mode for PCI Express Product Guide (PG346)

Document_ID
PG346
Release_Date
2026-08-07
Version
3.4 English
Note: USER_CLK (user_clk) in this section refers to pcie(n)_user_clk, which is also described in the Clock and Reset Interface section.

The CPM requires a 100, 125, or 250 MHz reference clock input. The following figure shows the clocking architecture. The user_clk clock can be used as the system clock.

Figure 1. USER_CLK Clocking Architecture

All user interface signals are timed with respect to the same clock (user_clk), which can have a frequency of 62.5, 125, or 250 MHz depending on the configured link speed and width. The user_clk should be used to interface with the CPM. With the user logic, any available clocks can be used.

Each link partner device shares the same reference clock source. The following figures show a system using a 100 MHz reference clock. Even if the device is part of an embedded system, if the system uses commercial PCI Express® root complexes or switches along with typical motherboard clocking schemes, synchronous clocking should be used.

Note: The following figures are high-level representations of the board layout. Ensure that coupling, termination, and details are correct when laying out a board.
Figure 2. Embedded System Using 100 MHz Reference Clock
Figure 3. Open System Add-In Card Using 100 MHz Reference Clock