This is the time interval at which ACR takes a decision to either increment or decrement the N or Maud in loop control mode. This counter runs on aud_mclk.
| Bit | Default Value | Access Type | Description |
|---|---|---|---|
| 31:16 | 0 | RO | Reserved |
| 15:0 | 0 | R/W | Specify the value of the sample interval. |