The s_axi_ctrl_aresetn is the AXI4-Lite
active-Low reset. It resets all the registers to their default values. The
ref_clk_resetn and acr_resetn are active-Low resets that
reset the ref_clk and acr_clk logic respectively. The
aud_mrst is a active-High reset that resets the loop control logic.