| Port Name | I/O | Description |
|---|---|---|
| reset/resetn | I | Reset (active-High)/resetn (active-Low): When asserted, asynchronously clears the internal state of the primitive, and causes the primitive to re-initiate the locking sequence when released |
| power_down | I | When asserted, places the clocking primitive into low power state, which stops the output clocks |
| input_clk_stopped | O | When asserted, indicates that the selected input clock is no longer toggling |
| locked | O | When asserted, indicates that the output clocks are stable and usable by downstream circuitry |
| locked_fb | O | When asserted, indicates that the feedback clock is stable. |
| s_axi_* | I/O | Refer to Appendix A of the Vivado Design Suite: AXI Reference Guide (UG1037). This signal is available only if dynamic reconfiguration is enabled. |
| locked_deskew1 | O | When asserted, indicates that the DESKEW PD1 Network clocks are stable. |
| locked_deskew2 | O | When asserted, indicates that the DESKEW PD2 Network clocks are stable. |
| clkfb_stopped | O | Asserted when the feedback clock is lost. |
| interrupt | O | Available when clock monitor is selected. This port gives the interrupts of the clock monitor feature |
| clk_oor [3:0] | O | Available when clock monitor is selected. The bits for this
port are high when input clock frequency is out of range than expected.
|
| clk_glitch [3:0] | O | Available when clock monitor is selected. The bits for this
port are high when there is a glitch in the input clock.
|
| clk_stop [3:0] | O | vailable when clock monitor is selected. The bits for this
port are high when the clock is stopped on the respective user clock.
|
Note: Exposure of every status and
control port is individually selectable. To enable interrupt register, you must write to the
interrupt enable register with all 1's. This allows you to enable interrupt for clock stop,
clock overrun, and clock underrun bits in the interrupt status register.