The following table shows the relationship between the fields in the AMD Vivado™ IDE and the user parameters (which can be viewed in the Tcl Console).
| Vivado IDE Parameter | User Parameter | Default Value |
|---|---|---|
|
Bus Direction
|
BUS_DIR | 0 |
BiDir Mode
|
BIDIR_MODE | 1 |
| Enable BIDIR state machine Range:
Note: This option is available only in
the case of BIDIR or Mix of BIDIR modes.
|
EN_BIDIR_SM | 0 |
|
Interface Speed (Mb/s) Range: 200-1800 Mb/s Note: The range is subjected to change based on below selections:
|
DATA_SPEED | 1000 |
|
PLL Clk Input Frequency (MHz) Range: 100-1099 MHz Note: The rage is subjected to change based on the speed grade
selected
|
INPUT_CLK_FREQ | 500.00 |
|
Clock to Data Relation (RX Strobe) Range:
|
CLK_TO_DATA_ALIGN | 4 |
|
PLL Clock Source Range:
|
PLL_CLK_SOURCE | BUFG_TO_PLL |
|
Enable Custom CDR Range:
|
ENABLE_CUSTOM_CDR | 0 |
|
TX, RX Serialization Factor Range: 2,4,8 |
TX/RX_SERIALIZATION_FACTOR | 8 |
|
Serialization Factor Range: 2,4,8 |
SERIALIZATION_FACTOR | 8 |
|
Select if PLL is included in core or Example Design Range:
|
PLL_IN_CORE | 0 |
|
Forwarded Clock Phase (TX Signal Type = Clk Fwd) Range:
|
CLK_FWD_PHASE | 0 |
|
Single Ended IO Standard Range: Varies with device |
SINGLE_IO_STD | NONE |
|
Differential IO Standard Range: Varies with device |
DIFFERENTIAL_IO_STD | NONE |
|
RIU Interface Range:
|
ENABLE_RIU_INTERFACE | 0 |
|
Enable Simple RIU Range:
|
SIMPLE_RIU | 0 |
|
Enable BitSlip Range:
|
ENABLE_BITSLIP | 0 |
|
Enable Data Bitslip Range:
|
ENABLE_DATA_BITSLIP | 0 |
|
3-state
|
DATA_TRISTATE | 1 |
| Number of Channels | BUS<0-16>_NUM_PINS | 1 |
| Signal Name | BUS<0-16>_SIG_NAME | Data_pins_0 |
|
Pin Direction
|
BUS<0-16>_DIR | None |
|
Signal IO Type
|
BUS<0-16>_IO_TYPE | SINGLE |
| Signal Type | BUS<0-16>_SIG_TYPE | Data |
| Enable Strobe | BUS<0-16>_STROBE_EN | False |
| Strobe Name | BUS<0-16>_STROBE_NAME | Strobe_0 |
| Enable WrClk | BUS<0-16>_WRCLK_EN | False |
| WrClk Name | BUS<0-16>_WRCLK_NAME | WrClk_0 |
|
Strobe IO Type
|
BUS<0-16>_STROBE_IO_TYPE | SINGLE |
|
WrClk IO Type
|
BUS<0-16>_WRCLK_IO_TYPE | SINGLE |
|
Application Data Width Range: 4 and 8 |
APPLICATION_DATA_WIDTH | 8 |
|
Application Range:
|
APPLICATION_TYPE | SOURCE_SYNCHRONOUS |
|
FIFO_WRCLK_OUT Range:
|
PLL_FIFO_WRITE_CLK_EN | False |
|
Reduce Control Signal Range:
|
REDUCE_CONTROL_SIG_EN | False |
|
IOB Power saving Range:
|
ENABLE_IOB_POWER_SAVING | Fallse |
| IOB Power control Range:
|
IOB_POWER_CONTROL | User Controlled |
| Enable Delay Control Signals Range:
|
DELAY_CTRL_SIG_EN | False |
| ENABLE CDR DEBUG SIGNALS Range:
|
ENABLE_CDR_DEBUG | False |
| Enable BLI Logic Range:
|
ENABLE_BLI | True |
| Enable Debug Ports Range:
|
ENBALE_DEBUG_PORTS | False |
| Enable ILA in Example Design Range:
|
ENABLE_ILA_IN_EXDES | False |
| Multi Banks are Part of a Triplet Range:
|
BANKS_IN_TRIPLET | False |
|
FIFO mode enablement Range:
|
FIFO_MODE_EN_GUI | False |
|
FIFO mode options Range:
|
FIFO_MODES | ASYNC |
|
FIFO read enable user control Range:
|
FIFO_RD_EN_CTRL | False |
| Strobe Selection (For PLL input) Range:
|
STROBE_SEL | 0 |
| PACKAGE | PACKAGE | 0.0 |
| CHANNEL | CHANNEL | 0.0 |
|
||