Lookup Specifications Tab - 4.0 English - PG319

Semi-Ternary CAM Search v4.0 LogiCORE IP Product Guide (PG319)

Document ID
PG319
Release Date
2025-05-29
Version
4.0 English
Figure 1. Lookup Specifications Parameters

Lookup Rate
This is the supported lookup rate of the CAM instance (expressed in million Lookups per second). In order to save resources, it is important not to set the lookup rate higher than required.
Fixed/Variable Rate
Enable variable lookup rate. Variable rate uses less RAM and logic resources for most configurations, but does not guarantee fixed lookup rate or fixed latency.
Note: This parameter is only available for STCAM.
Lookup Interface Frequency
This is the clock frequency for the Lookup Request and Response Interfaces, specified in MHz.
Enable Flow Control
Enable flow control for the lookup interface output. Flow control adds extra FIFOs for SINGLE_CLOCK mode, so the lookups can be stopped. Flow control is not needed if the m_axis_lkup_tready port always is high when the lookup response arrives.
Clocking Mode
Options available in this pull-down menu are: SINGLE CLOCK and DUAL CLOCK. When SINGLE CLOCK is selected the configuration parameter RAM Frequency is not available.
RAM Frequency
This is the clock frequency for the memories (block RAM/URAM) and the internal datapath, specified in MHz. Specifying a higher frequency RAM clock enables time division of the hardware resources, leading to significant resource savings. This configuration parameter is only available when CLOCKING_MODE = DUAL_CLOCK is selected.
Note: When CLOCKING_MODE = SINGLE CLOCK, RAM_FREQ = LOOKUP_INTERFACE_FREQ.