Clock Management - 4.0 English - PG317

Binary CAM Search v4.0 LogiCORE IP Product Guide (PG317)

Document ID
PG317
Release Date
2025-06-11
Version
4.0 English

If CLOCKING_MODE = DUAL CLOCK is selected, then the two clocks: LOOKUP_INTERFACE_FREQ and RAM_FREQ should be sourced/derived from the same clock generator (MMCM or PLL).