- Connect the Tokyo Electron Device Limited (TED) TB-FMCH-VFMC-DP module to the HPC FMC connector on the KCU105 board, to the
FMCP2 connector on the VCK190, to the HPC0 connector on the ZCU102, or to the FMCP
HSPC connector on the VCU118 depending on your design.
- Connect a USB cable (Type A to mini
B) from the host PC to the USB UART port on
the KCU105 for serial communication. For the
KCU105, ZCU102, or VCU118, use Type A to micro B type of USB cable. For the VCK190 board, connect the USB cable (Type A
to Type C) from the host PC to the USB port (U20).
- Connect a JTAG USB Platform cable or a USB Type A to Micro B cable from the
host PC to the board for programming BIT and ELF files.
- For pass-through or TX-only applications,
connect a DP cable from the TX port of the TED TB-FMCH-VFMC-DP module to a monitor, as shown
in the following figure.
- For pass-through or RX-only applications,
connect a DP cable from the RX port of the TED TB-FMCH-VFMC-DP module to a DP source (GPU),
as shown in the following figure.
Figure 1. KCU105 Board Setup
Figure 2. ZCU102 Board Setup