Error Response Faults - Error Response Faults - 1.2 English - PG293

AXI Protocol Firewall IP LogiCORE IP Product Guide (PG293)

Document ID
PG293
Release Date
2025-08-29
Version
1.2 English

The following in-band AXI error responses, observed on the MI, optionally block the firewall and/or signal an interrupt, when enabled in the SI-Side Interrupt Enable Register/MI-Side Interrupt Enable Register. The offending command cannot be prevented from propagating to the MI.

XILINX_RD_SLVERR
Detected Read SLVERR.
XILINX_RD_DECERR
Detected Read DECERR.
XILINX_WR_SLVERR
Detected Write SLVERR.
XILINX_WR_DECERR
Detected Write DECERR.