The following table shows the transceiver I/O ports for the 1G/10G/25G Ethernet Subsystem. See Clocking for details on each clock domain.
Name | I/O | Description | Clock Domain |
---|---|---|---|
gt_tx_reset | I | Reset for the gigabit transceiver (GT) TX. | Async |
gt_rx_reset | I | GT RX reset. | Async |
ctl_gt_reset_all | I | Active-High asynchronous reset for the transceiver startup Finite State Machine (FSM). This signal also initiates the reset sequence for the entire 1G/10G/25G Ethernet Subsystem. | Async |
gt_refclk_n | I | Differential reference clock input for the SerDes, negative phase. | See Clocking. |
gt_refclk_p | I | Differential reference clock input for the SerDes, positive phase. | See Clocking. |
rx_serdes_data_n0 | I | Serial data from the line; negative phase of the differential signal | See Clocking. |
rx_serdes_data_p0 | I | Serial data from the line; positive phase of the differential signal | See Clocking. |
tx_serdes_data_n0 | O | Serial data to the line; negative phase of the differential signal. | See Clocking. |
tx_serdes_data_p0 | O | Serial data to the line; positive phase of the differential signal. | See Clocking. |
tx_serdes_clk | O | When present, same as tx_clk_out. | See Clocking. |