Table 1. Snn_Entry Advanced Properties: CONFIG.ADVANCED_PROPERTIES dictionary keys: __view__ timing Snn_Entry
Name Description Format/Range/Dependencies
MMU_REGSLICE 1 MMU Register Slice

Enables or disables a register slice at the outer boundary of the SmartConnect port.

The exterior register slice is enabled by default but you can disable it via this advanced property to reduce area and latency (if it is known that the IP attached to the SmartConnect port is suitably pipelined).

  • Type: Integer
  • Values: 0, 1
  • Default: 1
TR_REGSLICE 1 Transaction Regulator Register Slice

Enables or disables a register slice on the interior pathway of the port's entry pipeline.

The interior register slice is enabled by default but you can disable it to reduce area and latency (if it is known that no adverse effect on timing closure will occur).

  • Type: Integer
  • Values: 0, 1
  • Default: 1
  1. This Advanced Property is ignored when SmartConnect is configured in AXI4-Lite Low Area Mode. When all of the endpoint slaves connected to the MI-side of the SmartConnect are 32-bit-wide AXI4-Lite slaves, the SmartConnect Hierarchical IP uses Low Area Mode to optimize for Area at the expense of performance. In Low Area Mode, all optional register slices are disabled. Instantiate and connect an AXI Register Slice core to any SI or MI of the SmartConnect, enabled per-channel as needed, if you observe a timing-critical path through the SI or MI.
Table 2. Snn_Buffer Advanced Properties: CONFIG.ADVANCED_PROPERTIES dictionary keys: __view__ timing Snn_Buffer
Name Description Format/Range/Dependencies
AR_SLR_PIPE

AW_SLR_PIPE

R_SLR_PIPE

W_SLR_PIPE

B_SLR_PIPE

Per-channel SLR Pipeline Control

Specifies number of pipeline stages that improve SLR-crossing in the corresponding channel's data buffer.

Refer to Constraining the Core for information on associated placement constraints to ensure the SLR crossing pipeline flops are placed correctly.

  • Type: Integer
  • Values: 0..3
  • Default: 0
AR_M_PIPE

AW_M_PIPE

W_M_PIPE

Per-channel Payload Pipeline Control

Enables or disables pipeline stages for channel payloads between the channel's Snn_Buffer and Switchboard.

The interior register slice is enabled by default but you can disable it to reduce area and latency (if it is known that no adverse effect on timing closure will occur).

  • Type: Integer
  • Values: 0..3
  • Default: 0
AR_M_SEND_PIPE

AW_M_SEND_PIPE

W_M_SEND_PIPE

Per-channel Handshake Pipeline Control

Enables or disables pipeline stages for channel handshakes between the Snn_Buffer and SmartConnect's channel switchboards.

  • Type: Integer
  • Values: 0, 1
  • Default: 1
AR_SYNC_STAGES

AW_SYNC_STAGES

R_SYNC_STAGES

W_SYNC_STAGES

B_SYNC_STAGES

Per-channel Asynchronous Clock Crossing Stages

Specifies the number of synchronization stages used in asynchronous clock domain conversion.

  • Type: Integer
  • Values: 2..8
  • Default: 3
Table 3. Mnn_Buffer Advanced Properties: CONFIG.ADVANCED_PROPERTIES dictionary keys: __view__ timing Mnn_Buffer
Name Description Format/Range/Dependencies
AR_SLR_PIPE

AW_SLR_PIPE

R_SLR_PIPE

W_SLR_PIPE

B_SLR_PIPE

Per-channel SLR Pipeline Control

Specifies number of pipeline stages that improve SLR-crossing in the corresponding channel's data buffer.

See Constraining the Core for information on associated placement constraints to ensure the SLR crossing pipeline flops are placed correctly.

  • Type: Integer
  • Values: 0..3
  • Default: 0
R_M_PIPE

B_M_PIPE

Per-channel Payload Pipeline Control

Enables or disables pipeline stages for channel payloads between the channel's Snn_Buffer and Switchboard

The interior register slice is enabled by default but you can disable it to reduce area and latency (if it is known that no adverse effect on timing closure will occur).

  • Type: Integer
  • Values: 0..3
  • Default: 0
R_M_SEND_PIPE

B_M_SEND_PIPE

Per-channel Handshake Pipeline Control

Enables or disables pipeline stages for channel handshakes between the Snn_Buffer and SmartConnect's channel switchboards.

  • Type: Integer
  • Values: 0, 1
  • Default: 1
AR_SYNC_STAGES AW_SYNC_STAGES R_SYNC_STAGES W_SYNC_STAGES B_SYNC_STAGES Per-channel Asynchronous Clock Crossing Stages

Specifies the number of synchronization stages used in asynchronous clock domain conversion.

  • Type: Integer
  • Values: 2..8
  • Default: 3
Table 4. Switchboard (SW0) Advanced Properties: CONFIG.ADVANCED_PROPERTIES dictionary keys: __view__ timing SW0
Name Description Format/Range/Dependencies
AR_M_PIPE

AW_M_PIPE

R_M_PIPE

W_M_PIPE

B_M_PIPE

Per-channel Payload Pipeline Control

Enables pipeline stages on the egress of the given channel switchboard.

  • Type: Integer
  • Values: 0..3
  • Default: 1
AR_S_PIPE

AW_S_PIPE

R_S_PIPE

W_S_PIPE

B_S_PIPE

Per-channel Payload Pipeline Control

Enables pipeline stages on the ingress of the given channel switchboard.

  • Type: Integer
  • Values: 0..3
  • Default: 0
Table 5. Mnn_Exit Advanced Properties: CONFIG.ADVANCED_PROPERTIES dictionary keys: __view__ timing Mnn_Exit
Name Description Format/Range/Dependencies
REGSLICE 1 Exit Register Slice

Enables or disables a register slice at the outer boundary of the SmartConnect port.

The exterior register slice is enabled by default but you can disable it via this advanced property to reduce area and latency (if it is known that the IP attached to the SmartConnect port is suitably pipelined).

  • Type: Integer
  • Values: 0,1
  • Default: 1
  1. This Advanced Property is ignored when SmartConnect is configured in AXI4-Lite Low Area Mode. When all of the endpoint slaves connected to the MI-side of the SmartConnect are 32-bit-wide AXI4-Lite slaves, the SmartConnect Hierarchical IP uses Low Area Mode to optimize for Area at the expense of performance. In Low Area Mode, all optional register slices are disabled. Instantiate and connect an AXI Register Slice core to any SI or MI of the SmartConnect, enabled per-channel as needed, if you observe a timing-critical path through the SI or MI.