This section lists the configuration parameters for the AXI SmartConnect core.

Table 3-1:      AXI SmartConnect Core Global Parameters 

Parameter Name

Default

Value

Format/Range

Description

NUM_SI

2

Integer (1-16)

Number of Slave Interfaces

NUM_MI

1

Integer (1-16)

Number of Master Interfaces

NUM_CLKS

1

Integer (1-33)

Number of clock inputs

HAS_ARESETN

1

0,1

Enable aresetn input

ADVANCED_PROPERTIES

 

String

Contains a Tcl dictionary specifying additional property assignments to control advanced features of the SmartConnect.