Upon completing the clock recovery phase of link training, the source transitions to the channel equalization phase. Once in the channel equalization phase, the software should enable adaptive equalization in DP159.
Address | Read/Write | Data | Description |
---|---|---|---|
0x4C | Write | 0x03 | Enable Adaptive Equalization |
0xFF | Write | 0x00 | Select Page0 |
0x15 | Write | 0x18 | Clear BERT counters and TST_INTQ latches |
0x18 | Read | BERT counters [7:0] read and error counters increment | |
0x19 | Read | BERT counters[11:8] read and error counters increment | |
0xFF | Write | 0x01 | Select Page1 |