Pass-Through Application (KC705 and KCU105) - 2.1 English

DisplayPort RX Subsystem LogiCORE IP Product Guide (PG233)

Document ID
PG233
Release Date
2023-05-25
Version
2.1 English

As soon as the application is executed, it checks if a Monitor is connected or not. If a monitor is already connected, then it starts up the following options as shown in the following figure to choose from (KC705).

Figure 1. DisplayPort User Console

Selecting either r or s puts the system in Pass-Through mode, where the Video received by RX is forwarded to TX. This configures the vid_phy_controller and sets up the DisplayPort for RX. If a DisplayPort Source (for example, GPU) is already connected to DP RX, then it starts the training. Else, the training happens when the cable is plugged in. As soon as the training is completed, the application starts the DP TX Subsystem. The video should be seen on the monitor once the TX is up. The previous figure shows the UART transcript. The transcript might differ based on the training done by GPU.