- Open the AMD Vivado™ Design Suite
and click Create Project.
- In the New Project window, enter a Project name, Project location, and click Next up to the Board/Part selection
window.
- In the Default Part window,
select the Board as per your requirement. Application Example Designs are
available for KC705, KCU105, and ZCU102. As an example, the AMD Kintex™ 7 KC705 board is selected.
- Click Finish.
- In the Flow Navigator, click Create
Block Design (BD). Select a name for BD and click OK.
- Right-click BD and click Add
IP. Search for DisplayPort and select either the DisplayPort 1.2
RX Subsystem IP (for RX only (ZCU102) or Pass-through (KC705, KCU105) designs)
or the DisplayPort 1.2 TX Subsystem IP (for TX only (ZCU102) or Pass-through
(KC705, KCU105) designs).
- Double-click the IP and go to the Application Example Design tab in the
Customize IP
window. Select the supported topology in the Application Example Design drop-down
box. Click OK and Save the block design.
- Right-click the DisplayPort
Subsystem IP under Design source in the Design tab and click Open IP Example Design.
- Choose Example project
directory and click OK.
- The following figure shows the Vivado IP integrator design. Choose the Generate Bitstream.
- Export the hardware (xsa) to the AMD Vitis™
software platform. Click .