SCU200 XP5IO Hardware Setup - SCU200 XP5IO Hardware Setup - 6.0 English - PG232

MIPI CSI-2 Receiver Subsystem Product Guide (PG232)

Document ID
PG232
Release Date
2026-07-08
Version
6.0 English
  1. Set up the hardware connections as shown in the following figure.

    1. Insert the ALINX FL1404 4-channel MIPI FMC Module on the SCU200 FMC slot, and connect the ALINX AN5020Camera sensor module to the Slot-1 of FL1404 using 20-pin ribbon flex cable.
    2. Connect the HDMI cable to the SCU200 HDMI port.

    3. Connect the other end of the HDMI cable to the HDMI monitor.
    4. Switch on the HDMI monitor, and select HDMI as the input source.
    5. Connect the USB-JTAG programming cable from host PC to JTAG type-A USB port of the board.
    6. Ensure that the SD card, board switches and jumpers are in position. Connect the USB UART and JTAG programming cables to the Windows host computer where xsdb and hw_server is running.
  2. Connect the power supply cable and turn on the SCU200 board
  3. Start a Hyper Terminal program on the host PC with the following settings:
    • Baud rate: 115200
    • Data Bits: 8
    • Parity: None
    • Stop Bits: 1
    • Flow Control: Non