SCU200 HPIO Hardware Setup - SCU200 HPIO Hardware Setup - 6.0 English - PG232

MIPI CSI-2 Receiver Subsystem Product Guide (PG232)

Document ID
PG232
Release Date
2026-07-08
Version
6.0 English
  1. Set up the hardware connections as shown in the following figure.

    1. Connect the SONY IMX219 camera module to the J31 connector of the SCU200 using a 22-pin flex cable.
    2. Connect the HDMI cable to the SCU200 HDMI port.

    3. Connect the other end of the HDMI cable to the HDMI monitor.
    4. Switch on the HDMI monitor, and select HDMI as the input source.
    5. Connect the USB-JTAG programming cable from host PC to JTAG type-A USB port of board.
    6. Ensure that the SD card, board switches, and jumpers are in position. Connect the USB UART and JTAG programming cables to the Windows host computer where xsdb and hw_server is running.
  2. Connect the power supply cable and turn on the SCU200 board.
  3. Start a Hyper Terminal program on the host PC with the following settings:
    • Baud rate: 115200
    • Data Bits: 8
    • Parity: None
    • Stop Bits: 1
    • Flow Control: None