Simplex TX Mode Simulation - 2.4 English - PG169

Integrated Interlaken 150G LogiCORE IP Product Guide (PG169)

Document ID
PG169
Release Date
2024-06-05
Version
2.4 English

As shown in the previous figure, only the ILKN Transmitter is enabled and packet generator enabled for the generation of packets in this mode of operation. For simulation, a partner test bench is instantiated to perform the functionality of the ILKN Receiver. This partner test bench has an ILKN receiver and a packet monitor to verify the received data form the generator.

Example design Packet generator supports both packet mode and burst mode in Simplex TX. However, you must change the DATA_FLOW_MODE parameter value in interlaken_*_segmented_lbus_pkt_gen.v according to the Receiver mode (that is, packet or burst). For example:

  • If Simplex RX is configured as packet mode, set DATA_FLOW_MODE to 1, or
  • If Simplex RX is configured as burst mode, set DATA_FLOW_MODE to 0.

The following figure shows the Simplex TX mode for simulation block diagram.

Figure 1. Simplex TX Mode Simulation Block Diagram