STAT_RX_CRC32_ERR[11:0] - 2.4 English - PG169

Integrated Interlaken 150G LogiCORE IP Product Guide (PG169)

Document ID
PG169
Release Date
2024-06-05
Version
2.4 English

When a bit in this bus is 1, it indicates that after the corresponding lane was word boundary synchronized, a CRC32 error was detected. This output is asserted for one clock period each time a CRC32 error is detected.

Note: CRC32 errors do not affect word boundary synchronized. They are only reported as status indicators. Keep a count of how many CRC32 errors were detected for each lane to examine the health of each individual lane over a period of time.
Note: The checking of the Diagnostic Word only checks the CRC32 and does not check whether or not the unused bits of the Diagnostic Word, Bits[57:34], are 0s as described in the specification.