The input DATA and output DATA channels share a
common tdata structure format but can have different
bit widths. All parallel data paths (refer to Parallel Data Channel Filters) and parallel data samples (refer to Super Sample Rate Filters) are contained in the tdata bus, with each path being sign extended to an 8-bit
boundary. The core does not use the extra bits on the input tdata.
The following figure shows the tdata structure for a case with two parallel paths (data
streams). In this case, bit growth is experienced between input and output—a path width
of 11-bits on the input grows to 13-bits on the output.
Figure 1. Tdata Structure for Input and Output DATA Channels

Note: The AXI4-Port
Structure pane on the Implementation Details Tab of the customization GUI displays the
bus structure of all AXI channels for the specified configuration.