The captured timestamp will always be presented out-of-band with TEMAC frame reception
using a dedicated AXI4-Stream interface. The signal definition for this is
defined in the following table.
A timing diagram showing the operation of this interface follows the table. To summarize,
the timestamp will be valid on the same clock cycle as the first data word of frame
data. This AXI4-Stream interface is synchronous to the TEMAC receive
clock.