Static Control - 3.0 English - PG125

AXI Traffic Generator LogiCORE IP Product Guide (PG125)

Document ID
PG125
Release Date
2023-10-18
Version
3.0 English

Static Control register allows you to start and stop the AXI Traffic Generator in Static mode.

Table 1. Static Mode Control (0x60)
Bits Name Reset Value Access Type Description
31:24 Version 0x20 R Version Value
23:2 Reserved N/A N/A Reserved
1 DONE 0x0 R/W1C

Transfer Done

0 = Indicates core is generating traffic when STEN is 1, else core is in idle mode

1 = Indicates traffic generation completed

This bit is set to 1 when the core is disabled by setting STTEN to 0 and the current transfer is completed.

This bit resets to 0 either writing 1 to this bit or enabling the core with STEN.

0 STEN 0x0 R/W

Static Enable

0 = Disable traffic generation

1 = Enable traffic generation

  1. W1C – Write 1 to Clear (to clear register bit, you must write 1 to corresponding bits).
  2. During traffic generation if the core is forced to stop traffic (either by writing STREN to 0 or using core_ext_stop pin) core completes the current transfer gracefully before stopping.