Extended Transfer Length - 3.0 English - PG125

AXI Traffic Generator LogiCORE IP Product Guide (PG125)

Document ID
PG125
Release Date
2023-10-18
Version
3.0 English

Extended Transfer Length register allows you to extend the length of packets. The value in Bits[7:0] of this register is concatenated to Bits[15:0] of the Transfer Length to determine the Length in a packet. This register is only available in the Streaming mode of operation

Table 1. Extended Transfer Length (0x50)
Bits Name Reset Value Access Type Description
31:8 Reserved N/A N/A Reserved
7:0 Ext-TLEN 0x0 R/W When Random Length in Streaming Config register is not set, Length programmed in this register is used. TLEN in a packet. This value is concatenated to a value in the Transfer Length Bits[15:0] to give a maximum value of 224 – 1 beats in the Streaming packet.