Enable Input (0x0098) Register - 8.2 English - PG103

Video Test Pattern Generator LogiCORE IP Product Guide (PG103)

Document ID
PG103
Release Date
2025-11-20
Version
8.2 English

The Enable Input register indicate whether to make use of video stream entering slave AXI4-Stream video interface.

  • 0x0 - Ignore the input video stream. The IP works the same way as AXI4-Stream slave is disabled although it has s_axi_video interface and connection.
  • 0x1 - Make use of input video stream.