The logic required to implement the RGMII transmitter logic is shown in Figure 1. The gtx_clk is a user-supplied 125 MHz reference clock source which is placed on global clock routing to provide the clock for all transmitter logic within the core, for the user-side logic which connects to the transmitter AXI4-Stream interface of the core.

Figure 1 shows how to use the physical transmitter interface of the core to create an external RGMII. The signal names and logic shown in this figure exactly match those delivered with the core. Figure 1 shows that the output transmitter signals are registered in device IOBs, using DDR registers, before driving them to the device pads.

For 7 series and Zynq 7000 families, the voltage standard used depends on the type of I/O used: HR I/O supports RGMII at 2.5V or lower and HP I/O only supports 1.8V or lower. Despite this being the defined RGMII voltage, most PHYs require 2.5V and therefore an external voltage converter is required to interoperate with any multi-standard PHY when using 7 series HP I/O.

Note: If the target FPGA family is AMD Artix™ 7 or AMD Kintex™ 7, the physical interface logic generated by default is for HR I/O. For Kintex 7 devices, which can contain both HR and HP I/O banks, the HP I/O scheme can be used when the RGMII interface pins are mapped to HP I/O banks.

The logic required to forward the transmitter clock is also shown. This logic uses an IOB output Double-Data-Rate (DDR) register. So, the clock signal produced incurs the same delay as the data and control signals. However, the clock signal is then routed through an output delay element (IODELAY) before connecting to the device pad. The result of this is to create a 2 ns delay, which places the rgmii_txc forwarded clock in the center of the data valid window for forwarded RGMII data and control signals.