A status report provides more information about the controller state. It is a multiple-line report that is generated in response to the S command, provided the controller is in the observation or idle states. The non-SSI device status report has the following format:
MF {8-digit hex value} Maximum Frame (linear count)
SN {2-digit hex value} Hardware SLR Number
SC {2-digit hex value} Current State
FC {2-digit hex value} Current Flags
FS {2-digit hex value} Feature Set
The SSI device status report is similar to the non-SSI device status report, but with a sub-report per SLR. The sub-reports are sorted by hardware SLR number. For example, a device with four SLRs generates a report in this format:
MF {8-digit hex value} Maximum Frame (linear count)
SN {2-digit hex value} Hardware SLR Number
SC {2-digit hex value} Current State for this Hardware SLR
FC {2-digit hex value} Current Flags for this Hardware SLR
FS {2-digit hex value} Feature Set
MF {8-digit hex value} Maximum Frame (linear count)
SN {2-digit hex value} Hardware SLR Number
SC {2-digit hex value} Current State for this Hardware SLR
FC {2-digit hex value} Current Flags for this Hardware SLR
FS {2-digit hex value} Feature Set
MF {8-digit hex value} Maximum Frame (linear count)
SN {2-digit hex value} Hardware SLR Number
SC {2-digit hex value} Current State for this Hardware SLR
FC {2-digit hex value} Current Flags for this Hardware SLR
FS {2-digit hex value} Feature Set
MF {8-digit hex value} Maximum Frame (linear count)
SN {2-digit hex value} Hardware SLR Number
SC {2-digit hex value} Current State for this Hardware SLR
FC {2-digit hex value} Current Flags for this Hardware SLR
FS {2-digit hex value} Feature Set