Table: Troubleshooting Third-Party Interfaces describes how to troubleshoot third-party interfaces.
Symptom |
Solution |
---|---|
Severe color distortion or color-swap when interfacing to third-party video IP. |
Verify that the color component logical addressing on the AXI4-Stream
TDATA
signal is in according to
Core Interfaces and Register Space
. If misaligned:
|
Severe color distortion or color-swap when processing video written to external memory using the AXI-VDMA core. |
Unless the particular software driver was developed with the AXI4-Stream TDATA signal color component assignments described in Core Interfaces and Register Space , there are no guarantees that the software correctly identifies bits corresponding to color components.
Verify that the color component logical addressing
TDATA
is in alignment with the data format expected by the software drivers reading/writing external memory. If misaligned:
|