AC Voltage Overshoot 1 | % of UI 2 at –40°C to 100°C | AC Voltage Undershoot 1 | % of UI 2 at –40°C to 100°C |
---|---|---|---|
VCCO + 0.20 | 100% | –0.20 | 100% |
VCCO + 0.25 | 100% | –0.25 | 75% |
VCCO + 0.30 | 75% | –0.30 | 75% |
VCCO + 0.35 | 75% | –0.35 | 75% |
VCCO + 0.40 | 75% | –0.40 | 60% |
VCCO + 0.45 | 50% | –0.45 | 30% |
VCCO + 0.50 | 30% | –0.50 | 0% |
VCCO + 0.55 | 20% | –0.55 | 0% |
VCCO + 0.60 | 20% | –0.60 | 0% |
VCCO + 0.65 | 10% | –0.65 | 0% |
VCCO + 0.70 | 10% | –0.70 | 0% |
VCCO + 0.75 | 10% | –0.75 | 0% |
VCCO + 0.80 | 10% | –0.80 | 0% |
VCCO + 0.85 | 8% | –0.85 | 0% |
VCCO + 0.90 | 6% | –0.90 | 0% |
VCCO + 0.95 | 2% | –0.95 | 0% |
|
AC Voltage Overshoot 1 | % of UI 2 at –40°C to 100°C | AC Voltage Undershoot 1 | % of UI 2 at –40°C to 100°C |
---|---|---|---|
VCCO + 0.20 | 100% | –0.20 | 100% |
VCCO + 0.25 | 100% | –0.25 | 100% |
VCCO + 0.30 | 100% | –0.30 | 10% |
VCCO + 0.35 | 100% | –0.35 | 0% |
VCCO + 0.40 | 96% | –0.40 | 0% |
VCCO + 0.45 | 2% | –0.45 | 0% |
|