| Symbol | Description 1, 2 | Min | Typ | Max | Units |
|---|---|---|---|---|---|
|
FPGA Logic |
|||||
| VCCINT | Internal supply voltage | 0.825 | 0.850 | 0.876 | V |
| For -1LI (VCCINT = 0.72V) devices: internal supply voltage | 0.698 | 0.720 | 0.742 | V | |
| VCCINT_IO 3 |
Internal supply voltage for the I/O banks |
0.825 | 0.850 | 0.876 | V |
| For -1LI (VCCINT = 0.72V) devices: internal supply voltage for the I/O banks | 0.825 | 0.850 | 0.876 | V | |
| VCCBRAM 3 | Block RAM supply voltage | 0.825 | 0.850 | 0.876 | V |
| VCCAUX 7 | Auxiliary supply voltage | 1.746 | 1.800 | 1.854 | V |
| VCCO 4 | Supply voltage for HD I/O banks 5 | 1.140 | – | 3.400 | V |
| Supply voltage for HP I/O banks and configuration bank 0 6 | 0.950 | – | 1.900 | V | |
| VCCAUX_IO 7 | Auxiliary I/O supply voltage | 1.746 | 1.800 | 1.854 | V |
| VIN 8, 9 | I/O input voltage | –0.200 | – | VCCO + 0.200 | V |
| IIN 10 |
Maximum current through any pin in a powered or unpowered bank when forward biasing the clamp diode |
– | – | 10 | mA |
| VBATT 11 | Battery voltage | 1.000 | – | 1.890 | V |
|
GTH or GTY Transceiver |
|||||
| VMGTAVCC 12 |
Analog supply voltage for the GTH or GTY transceiver |
0.873 | 0.900 | 0.927 | V |
| VMGTAVTT 12 |
Analog supply voltage for the GTH or GTY transmitter and receiver termination circuits |
1.164 | 1.200 | 1.236 | V |
| VMGTVCCAUX 12 |
Auxiliary analog QPLL voltage supply for the transceivers |
1.746 | 1.800 | 1.854 | V |
| VMGTAVTTRCAL 12 |
Analog supply voltage for the resistor calibration circuit of the GTH or GTY transceiver column |
1.164 | 1.200 | 1.236 | V |
|
System Monitor |
|||||
| VCCADC |
System Monitor supply relative to GNDADC |
1.746 | 1.800 | 1.854 | V |
| VREFP |
System Monitor externally supplied reference voltage relative to GNDADC |
1.200 | 1.250 | 1.300 | V |
|
Temperature |
|||||
| Tj 13 | Junction temperature operating range for extended (E) temperature devices | 0 | – | 100 | °C |
| Junction temperature operating range for industrial (I) temperature devices | –40 | – | 100 | °C | |
| Junction temperature operating range for automotive (Q) temperature devices | –40 | – | 125 | °C | |
| Junction temperature operating range for eFUSE programming 14 | –40 | – | 125 | °C | |
|
|||||