Table 1 shows the minimum current, in addition to ICCQ maximum, required by each Artix UltraScale+ FPGA for proper power-on and configuration. If these current minimums are met, the device powers on after all supplies have passed through their power-on reset threshold voltages. The device must not be configured until after VCCINT is applied. Once initialized and configured, use the Xilinx Power Estimator (XPE) spreadsheet tool (download at www.amd.com/power) to estimate current drain on these supplies. XPE is also used to estimate power-on current for all supplies.
| Device | ICCINTMIN | ICCBRAMMIN + ICCINT_IOMIN | ICCOMIN | ICCAUXMIN + ICCAUX_IOMIN | Units |
|---|---|---|---|---|---|
| XCAU7P XAAU7P |
ICCINTQ + 770 | ICCBRAMQ + ICCINT_IOQ + 409 | ICCOQ + 50 | ICCAUXQ + ICCAUX_IOQ + 386 | mA |
| XCAU10P XAAU10P |
ICCINTQ + 770 | ICCBRAMQ + ICCINT_IOQ + 409 | ICCOQ + 50 | ICCAUXQ + ICCAUX_IOQ + 386 | mA |
| XCAU15P XAAU15P |
ICCINTQ + 770 | ICCBRAMQ + ICCINT_IOQ + 409 | ICCOQ + 50 | ICCAUXQ + ICCAUX_IOQ + 386 | mA |
| XCAU20P | ICCINTQ + 770 | ICCBRAMQ + ICCINT_IOQ + 476 | ICCOQ + 50 | ICCAUXQ + ICCAUX_IOQ + 515 | mA |
| XCAU25P | ICCINTQ + 770 | ICCBRAMQ + ICCINT_IOQ + 476 | ICCOQ + 50 | ICCAUXQ + ICCAUX_IOQ + 515 | mA |
| Symbol | Description | Min | Max | Units |
|---|---|---|---|---|
| TVCCINT | Ramp time from GND to 95% of VCCINT | 0.2 | 40 | ms |
| TVCCINT_IO | Ramp time from GND to 95% of VCCINT_IO | 0.2 | 40 | ms |
| TVCCO | Ramp time from GND to 95% of VCCO | 0.2 | 40 | ms |
| TVCCAUX | Ramp time from GND to 95% of VCCAUX | 0.2 | 40 | ms |
| TVCCBRAM | Ramp time from GND to 95% of VCCBRAM | 0.2 | 40 | ms |
| TMGTAVCC | Ramp time from GND to 95% of VMGTAVCC | 0.2 | 40 | ms |
| TMGTAVTT | Ramp time from GND to 95% of VMGTAVTT | 0.2 | 40 | ms |
| TMGTVCCAUX | Ramp time from GND to 95% of VMGTVCCAUX | 0.2 | 40 | ms |