The parameters in this section provide the necessary values for calculating timing budgets for clock transmitter and receiver data-valid windows.
| Symbol | Description | Device | Package | Value | Units |
|---|---|---|---|---|---|
| PKGSKEW | Package Skew 1, 2 | XCSU10P | CMVA361 | 56 | ps |
| CMVA529 | 58 | ps | |||
| SBVB625 | 81 | ps | |||
| XCSU25P | CMVA361 | 56 | ps | ||
| CMVA529 | 58 | ps | |||
| SBVB625 | 81 | ps | |||
| XCSU35P | CMVA361 | 56 | ps | ||
| CMVA529 | 58 | ps | |||
| SBVB625 | 81 | ps | |||
| XCSU45P | CMVE529 | ||||
| SBVD529 | 69 | ps | |||
| SBVB625 | 125 | ps | |||
| XCSU60P | CMVE529 | ||||
| SBVD529 | 69 | ps | |||
| SBVB625 | 125 | ps | |||
| XCSU65P | CMVB529 | ||||
| SBVC529 | |||||
| SBVF784 | |||||
| SBVG784 | |||||
| SBVA1024 | |||||
| XCSU100P | CMVB529 | ||||
| SBVC529 | |||||
| SBVF784 | |||||
| SBVG784 | |||||
| SBVA1024 | |||||
| XCSU150P | SBVF784 | 114 | ps | ||
| SBVG784 | 97 | ps | |||
| SBVF900 | 97 | ps | |||
| SBVA1024 | 92 | ps | |||
| NBVA1089 | 119 | ps | |||
| XCSU200P | SBVF784 | 114 | ps | ||
| SBVG784 | 97 | ps | |||
| SBVF900 | 97 | ps | |||
| SBVA1024 | 92 | ps | |||
| NBVA1089 | 119 | ps | |||
| PKGSKEW (Cont'd) | Package Skew 1, 2 | XASU35P | CMVA529 | ||
|
|||||