The parameters in this section provide the necessary values for calculating timing budgets for clock transmitter and receiver data-valid windows.
Symbol | Description | Device | Package | Value | Units |
---|---|---|---|---|---|
PKGSKEW | Package Skew 1, 2 | XCVU3P | FFVC1517 | 197 | ps |
XCVU5P | FLVA2104 | 175 | ps | ||
FLVB2104 | 225 | ps | |||
FLVC2104 | 216 | ps | |||
XCVU7P | FLVA2104 | 175 | ps | ||
FLVB2104 | 225 | ps | |||
FLVC2104 | 216 | ps | |||
XCVU9P | FLGA2104 | 217 | ps | ||
FLGB2104 | 275 | ps | |||
FLGC2104 | 299 | ps | |||
FSGD2104 | 229 | ps | |||
FLGA2577 | 149 | ps | |||
XCVU11P | FLGF1924 | 180 | ps | ||
FLGB2104 | 216 | ps | |||
FLGC2104 | 175 | ps | |||
FSGD2104 | 224 | ps | |||
FLGA2577 | 154 | ps | |||
XCVU13P | FHGA2104 | 215 | ps | ||
FHGB2104 | 259 | ps | |||
FHGC2104 | 182 | ps | |||
FIGD2104 | 198 | ps | |||
FLGA2577 | 140 | ps | |||
PKGSKEW (cont'd) | Package Skew (cont'd) 1, 2 | XCVU19P | FSVA3824 | 323 | ps |
FSVB3824 | 246 | ps | |||
XCVU23P | VSVA1365 | 134 | ps | ||
FSVJ1760 | 187 | ps | |||
XCVU27P | FIGD2104 | 198 | ps | ||
FSGA2577 | 139 | ps | |||
XCVU29P | FIGD2104 | 198 | ps | ||
FSGA2577 | 139 | ps | |||
XCVU31P | FSVH1924 | 165 | ps | ||
XCVU33P | FSVH2104 | 194 | ps | ||
XCVU35P | FSVH2104 | 200 | ps | ||
FSVH2892 | 241 | ps | |||
XCVU37P | FSVH2892 | 278 | ps | ||
XCVU45P | FSVH2104 | 200 | ps | ||
FSVH2892 | 241 | ps | |||
XCVU47P | FSVH2892 | 278 | ps | ||
XCVU57P | FSVK2892 | 278 | ps | ||
XQVU3P | FFRC1517 | 176 | ps | ||
XQVU7P | FLRA2104 | 175 | ps | ||
FLRB2104 | 224 | ps | |||
XQVU11P | FLRC2104 | 174 | ps | ||
|