This section provides the performance characteristics
of some common functions and designs implemented in the Virtex UltraScale+ FPGAs. These values are subject to the same guidelines as the
AC Switching Characteristics section.
In each of the
following LVDS performance tables, the I/O bank type is either high performance (HP) or
high density (HD).
In LVDS component mode:
- For the input/output registers in HP I/O banks, the Vivado tools limit clock frequencies to 312.9 MHz for all
speed grades.
- For IDDR in HP I/O banks, Vivado
tools limit clock frequencies to 625.0 MHz for all speed grades.
- For ODDR in HP I/O banks, Vivado
tools limit clock frequencies to 625.0 MHz for all speed grades.
Table 1. LVDS Component Mode Performance
Description |
I/O Bank Type |
Speed Grade and VCCINT Operating Voltages |
Units |
0.90V |
0.85V |
0.72V |
-3 |
-2 |
-1 |
-2 |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
LVDS TX DDR (OSERDES 4:1, 8:1) |
HP |
0 |
1250 |
0 |
1250 |
0 |
1250 |
0 |
1250 |
Mb/s |
LVDS TX SDR (OSERDES 2:1, 4:1) |
HP |
0 |
625 |
0 |
625 |
0 |
625 |
0 |
625 |
Mb/s |
LVDS RX DDR (ISERDES 1:4, 1:8)
1
|
HP |
0 |
1250 |
0 |
1250 |
0 |
1250 |
0 |
1250 |
Mb/s |
LVDS RX DDR |
HD |
0 |
250 |
0 |
250 |
0 |
250 |
0 |
250 |
Mb/s |
LVDS RX SDR (ISERDES 1:2, 1:4)
1
|
HP |
0 |
625 |
0 |
625 |
0 |
625 |
0 |
625 |
Mb/s |
LVDS RX SDR |
HD |
0 |
125 |
0 |
125 |
0 |
125 |
0 |
125 |
Mb/s |
- LVDS receivers are typically
bounded with certain applications to achieve maximum performance. Package skews
are not included and should be removed through PCB routing.
|
Table 2. LVDS Native Mode Performance
Description
1, 2
|
DATA_WIDTH |
I/O Bank Type |
Speed Grade and VCCINT Operating Voltages |
Units |
0.90V |
0.85V |
0.72V |
-3 |
-2 |
-1 |
-2 |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
LVDS TX DDR (TX_BITSLICE) |
4 |
HP |
375 |
1600 |
375 |
1600 |
375 |
1600 |
375 |
1400 |
Mb/s |
8 |
375 |
1600 |
375 |
1600 |
375 |
1600 |
375 |
1600 |
Mb/s |
LVDS TX SDR (TX_BITSLICE) |
4 |
HP |
187.5 |
800 |
187.5 |
800 |
187.5 |
800 |
187.5 |
700 |
Mb/s |
8 |
187.5 |
800 |
187.5 |
800 |
187.5 |
800 |
187.5 |
800 |
Mb/s |
LVDS RX DDR (RX_BITSLICE)
3
|
4 |
HP |
375 |
1600
4
|
375 |
1600
4
|
375 |
1600
4
|
375 |
1400
4
|
Mb/s |
8 |
375 |
1600
4
|
375 |
1600
4
|
375 |
1600
4
|
375 |
1600
4
|
Mb/s |
LVDS RX SDR (RX_BITSLICE)
3
|
4 |
HP |
187.5 |
800 |
187.5 |
800 |
187.5 |
800 |
187.5 |
700 |
Mb/s |
8 |
187.5 |
800 |
187.5 |
800 |
187.5 |
800 |
187.5 |
800 |
Mb/s |
- Native mode is supported
through the
High-Speed SelectIO Interface
Wizard
available with the Vivado Design Suite. The performance values assume a source-synchronous
interface.
- PLL settings can restrict the
minimum allowable data rate. For example, when using the PLL with
CLKOUTPHY_MODE = VCO_HALF the minimum frequency is PLL_FVCOMIN/2.
- LVDS receivers are
typically bounded with certain applications to achieve maximum performance.
Package skews are not included and should be removed through PCB routing.
- Asynchronous receiver
performance is limited to 1300 Mb/s for -3/-2 speed grades and to 1250 Mb/s for -1
speed grades.
|
Table 3. MIPI D-PHY Performance
Description |
I/O Bank Type |
Speed Grade and VCCINT Operating Voltages |
Units |
0.90V |
0.85V |
0.72V |
-3 |
-2 |
-1 |
-2 |
MIPI D-PHY transmitter or receiver |
HP |
1500 |
1500 |
1260 |
1500
1
|
Mb/s |
- Devices in the -2L (0.72) speed grade require Vivado
tools 2024.1 or later for data rates greater than 1260 Mb/s.
|
Table 4. LVDS Native-Mode 1000BASE-X Support
Description
1
|
I/O Bank Type |
Speed Grade and VCCINT Operating Voltages |
0.90V |
0.85V |
0.72V |
-3 |
-2 |
-1 |
-2 |
1000BASE-X |
HP |
Yes |
- 1000BASE-X support is based on the
IEEE Standard for CSMA/CD Access Method and Physical
Layer Specifications (IEEE Std 802.3-2008).
|
The following table provides the maximum data rates for applicable memory
standards using the Virtex UltraScale+ FPGA memory PHY.
Refer to
Memory Solutions
for the
complete list of memory interface standards supported and detailed specifications. The final
performance of the memory interface is determined through a complete design implemented in
the Vivado Design Suite, following guidelines in the
UltraScale
Architecture PCB Design User Guide (UG583), electrical analysis, and
characterization of the system.
Table 5. Maximum Physical Interface (PHY) Rate for Memory Interfaces
Memory Standard |
DRAM Type |
Speed Grade and VCCINT Operating Voltages |
Units |
0.90V |
0.85V |
0.72V |
-3 |
-2 |
-1 |
-2 |
DDR4 |
Single rank component |
2666 |
2666 |
2400 |
2400 |
Mb/s |
1 rank DIMM
1, 2,
3
|
2400 |
2400 |
2133 |
2133 |
Mb/s |
2 rank DIMM
1, 4
|
2133 |
2133 |
1866 |
1866 |
Mb/s |
4 rank DIMM
1, 5
|
1600 |
1600 |
1333 |
1333 |
Mb/s |
DDR3 |
Single rank component |
2133 |
2133 |
2133 |
2133 |
Mb/s |
1 rank DIMM
1, 2
|
1866 |
1866 |
1866 |
1866 |
Mb/s |
2 rank DIMM
1, 4
|
1600 |
1600 |
1600 |
1600 |
Mb/s |
4 rank DIMM
1, 5
|
1066 |
1066 |
1066 |
1066 |
Mb/s |
DDR3L |
Single rank component |
1866 |
1866 |
1866 |
1866 |
Mb/s |
1 rank DIMM
1, 2
|
1600 |
1600 |
1600 |
1600 |
Mb/s |
2 rank DIMM
1, 4
|
1333 |
1333 |
1333 |
1333 |
Mb/s |
4 rank DIMM
1, 5
|
800 |
800 |
800 |
800 |
Mb/s |
QDR II+ |
Single rank component
6
|
633 |
633 |
600 |
600 |
MHz |
RLDRAM 3 |
Single rank component |
1200 |
1200 |
1066 |
1066 |
MHz |
QDR IV XP |
Single rank component |
1066 |
1066 |
1066 |
933 |
MHz |
LPDDR3 |
Single rank component |
1600 |
1600 |
1600 |
1600 |
Mb/s |
- Dual in-line memory module (DIMM)
includes RDIMM, SODIMM, UDIMM, and LRDIMM.
- Includes: 1 rank 1 slot, DDP 2 rank,
LRDIMM 2 or 4 rank 1 slot.
- For the DDR4 DDP components at -3 and
-2 (VCCINT = 0.85V) speed grades, the maximum data
rate is 2133 Mb/s for six or more DDP devices. For five or less DDP devices, use
the single rank DIMM data rates for the -3 and -2 (VCCINT = 0.85V) speed grades.
- Includes: 2 rank 1 slot, 1 rank 2
slot, LRDIMM 2 rank 2 slot.
- Includes: 2 rank 2 slot, 4 rank 1
slot.
- The QDRII+ performance specifications
are for burst-length 4 (BL = 4) implementations.
|