Recommended Operating Conditions

Kintex UltraScale+ FPGAs Data Sheet: DC and AC Switching Characteristics (DS922)

Document ID
DS922
Release Date
2024-08-09
Revision
1.18 English
Table 1. Recommended Operating Conditions
Symbol Description 1, 2 Min Typ Max Units

FPGA Logic

VCCINT

Internal supply voltage

0.825 0.850 0.876 V

For -1LI and -2LE (VCCINT = 0.72V) devices: internal supply voltage

0.698 0.720 0.742 V

For -3E devices: internal supply voltage

0.873 0.900 0.927 V
VCCINT_IO 3

Internal supply voltage for the I/O banks

0.825 0.850 0.876 V

For -1LI and -2LE (VCCINT = 0.72V) devices: internal supply voltage for the I/O banks

0.825 0.850 0.876 V

For -3E devices: internal supply voltage for the I/O banks

0.873 0.900 0.927 V
VCCBRAM Block RAM and UltraRAM supply voltage 0.825 0.850 0.876 V
For -3E devices: block RAM and UltraRAM supply voltage 0.873 0.900 0.927 V
VCCAUX Auxiliary supply voltage 1.746 1.800 1.854 V
VCCO 4 Supply voltage for HD I/O banks 5 1.140 3.400 V
Supply voltage for HP I/O banks and configuration bank 0 6 0.950 1.900 V
VCCAUX_IO 7 Auxiliary I/O supply voltage 1.746 1.800 1.854 V
VIN 8, 9 I/O input voltage –0.200 VCCO + 0.200 V
IIN 10

Maximum current through any pin in a powered or unpowered bank when forward biasing the clamp diode

10 mA
VBATT 11 Battery voltage 1.000 1.890 V

GTH or GTY Transceiver

VMGTAVCC 12

Analog supply voltage for the GTH or GTY transceiver

0.873 0.900 0.927 V
VMGTAVTT 12

Analog supply voltage for the GTH or GTY transmitter and receiver termination circuits

1.164 1.200 1.236 V
VMGTVCCAUX 12

Auxiliary analog QPLL voltage supply for the transceivers

1.746 1.800 1.854 V
VMGTAVTTRCAL 12

Analog supply voltage for the resistor calibration circuit of the GTH or GTY transceiver column

1.164 1.200 1.236 V

System Monitor

VCCADC

System Monitor supply relative to GNDADC

1.746 1.800 1.854 V
VREFP

System Monitor externally supplied reference voltage relative to GNDADC

1.200 1.250 1.300 V

Temperature

Tj 13 Junction temperature operating range for extended (E) temperature devices 14 0 100 °C
Junction temperature operating range for industrial (I) temperature devices –40 100 °C
Junction temperature operating range for military (M) temperature devices –55 125 °C
Junction temperature operating range for eFUSE programming 15 –40 125 °C
  1. All voltages are relative to GND, assuming supplies are present.
  2. For the design of the power distribution system consult the UltraScale Architecture PCB Design User Guide (UG583).
  3. VCCINT_IO must be connected to VCCBRAM.
  4. For VCCO_0, the recommended nominal operating voltage is 1.5V or 1.8V, and the minimum voltage for power on and during configuration is 1.425V. After configuration, data is retained even if VCCO drops to 0V.
  5. Includes VCCO of 1.2V, 1.35V, 1.5V, 1.8V, and 2.5V at ±5%, and 3.3V at +3/–5%.
  6. Includes VCCO of 1.0V, 1.2V, 1.35V, 1.5V, and 1.8V at ±5%.
  7. VCCAUX_IO must be connected to VCCAUX.
  8. The lower absolute voltage specification always applies.
  9. VIN for the POR_OVERRIDE pin is unique. POR_OVERRIDE must be connected to either GND (default) or VCCINT. See TPOR in Configuration Switching Characteristics for additional information.
  10. A total of 200 mA per bank should not be exceeded.
  11. If battery is not used, connect VBATT to either GND or VCCAUX.
  12. Each voltage listed requires filtering as described in the UltraScale Architecture GTH Transceivers User Guide (UG576) or the UltraScale Architecture GTY Transceivers User Guide (UG578) .
  13. AMD recommends measuring the Tj of a device using the system monitor as described in the UltraScale Architecture System Monitor User Guide (UG580). The system monitor temperature measurement errors (that are described in Table 1) must be accounted for in your design. For example, when using the system monitor with an external reference of 1.25V, and when the system monitor reports 97°C, there is a measurement error ±3°C. A reading of 97°C is considered the maximum adjusted Tj (100°C – 3°C = 97°C).
  14. Devices labeled with the speed/temperature grade of -2LE can operate for a limited time at a junction temperature between 100°C and 110°C. Timing parameters adhere to the same speed file at 110°C as they do below 110°C, regardless of operating voltage (nominal voltage of 0.85V or a low-voltage of 0.72V). Operation up to Tj = 110°C is limited to 1% of the device lifetime and can occur sequentially or at regular intervals as long as the total time does not exceed 1% of the device lifetime.
  15. Do not program eFUSE during device configuration (e.g., during configuration, during configuration readback, or when readback CRC is active).