Table 1 shows the minimum current, in addition to ICCQ maximum, required by each Kintex UltraScale+ FPGA for proper power-on and configuration. If these current minimums are met, the device powers on after all supplies have passed through their power-on reset threshold voltages. The device must not be configured until after VCCINT is applied. Once initialized and configured, use the Xilinx Power Estimator (XPE) spreadsheet tool (download at www.amd.com/power) to estimate current drain on these supplies. XPE is also used to estimate power-on current for all supplies.
Device | ICCINTMIN | ICCINT_IOMIN + ICCBRAMMIN | ICCOMIN | ICCAUXMIN + ICCAUX_IOMIN | Units |
---|---|---|---|---|---|
XCKU3P | ICCINTQ + 770 | ICCBRAMQ + ICCINT_IOQ + 229 | ICCOQ + 50 | ICCAUXQ + ICCAUX_IOQ + 386 | mA |
XCKU5P XQKU5P |
ICCINTQ + 770 | ICCBRAMQ + ICCINT_IOQ + 305 | ICCOQ + 50 | ICCAUXQ + ICCAUX_IOQ + 515 | mA |
XCKU9P | ICCINTQ + 1800 | ICCBRAMQ + ICCINT_IOQ + 600 | ICCOQ + 50 | ICCAUXQ + ICCAUX_IOQ + 650 | mA |
XCKU11P | ICCINTQ + 1961 | ICCBRAMQ + ICCINT_IOQ + 654 | ICCOQ + 55 | ICCAUXQ + ICCAUX_IOQ + 709 | mA |
XCKU13P | ICCINTQ + 2242 | ICCBRAMQ + ICCINT_IOQ + 748 | ICCOQ + 63 | ICCAUXQ + ICCAUX_IOQ + 810 | mA |
XCKU15P XQKU15P |
ICCINTQ + 3433 | ICCBRAMQ + ICCINT_IOQ + 1145 | ICCOQ + 96 | ICCAUXQ + ICCAUX_IOQ + 1240 | mA |
XCKU19P | ICCINTQ + 5225 | ICCBRAMQ + ICCINT_IOQ + 1751 | ICCOQ + 131 | ICCAUXQ + ICCAUX_IOQ + 915 | mA |
Symbol | Description | Min | Max | Units |
---|---|---|---|---|
TVCCINT | Ramp time from GND to 95% of VCCINT | 0.2 | 40 | ms |
TVCCINT_IO | Ramp time from GND to 95% of VCCINT_IO | 0.2 | 40 | ms |
TVCCO | Ramp time from GND to 95% of VCCO | 0.2 | 40 | ms |
TVCCAUX | Ramp time from GND to 95% of VCCAUX | 0.2 | 40 | ms |
TVCCBRAM | Ramp time from GND to 95% of VCCBRAM | 0.2 | 40 | ms |
TMGTAVCC | Ramp time from GND to 95% of VMGTAVCC | 0.2 | 40 | ms |
TMGTAVTT | Ramp time from GND to 95% of VMGTAVTT | 0.2 | 40 | ms |
TMGTVCCAUX | Ramp time from GND to 95% of VMGTVCCAUX | 0.2 | 40 | ms |