AMD Solarflare X4522 Ethernet adapters support airflow in either direction:

  • Normal flow, where airflow is out from the I/O bracket.
  • Reverse flow, where airflow is into the I/O bracket.
Figure 1. Airflow Direction for X4522 Ethernet Adapters
The following table shows requirements for AMD Solarflare X4522 Ethernet adapters that are dependent on airflow direction.
Table 1. Airflow Direction Dependent Requirements
Specification Requirements
Inlet temperature ≤ 55°C
Inlet air speed ≥ 250 LFM uniform velocity
Minimum air velocity pressure 0.7 inAq
SFP case temperature for airflow entering PCIe bracket SFP (≤ 1.5W) case should be rated 70°C
SFP case temperature for airflow exiting PCIe bracket SFP (≤ 1.5W) case should be rated 85°C
Airflow entering PCIe bracket area 66.87 mm x 13.18 mm
Airflow exiting PCIe bracket area 56.51 mm x 20.33 mm