The following tables provide the required airflow rate and airflow speed to the V80 card under various operating conditions. The thermal design power (TDP) of the V80 card might fluctuate depending on factors such as inlet temperature, CFM/LFM airflow conditions, and the card's placement within the server. The LFM/CFM values for the V80 card, as indicated in the following tables, are significantly lower when the QSFP power is at 3.2W.
Inlet Temperature to the Card (°C) |
CFM | LFM | Static Pressure |
---|---|---|---|
25 | 17.8 | 413 | 0.24 |
30 | 20.8 | 482 | 0.30 |
35 | 24.6 | 573 | 0.38 |
40 | 29.9 | 695 | 0.52 |
Inlet Temperature to the Card (°C) |
CFM | LFM | Static Pressure |
---|---|---|---|
25 | 19.8 | 460 | 0.28 |
30 | 23.2 | 538 | 0.35 |
35 | 27.5 | 640 | 0.46 |
Inlet Temperature to the Card (°C) |
CFM | LFM | Static Pressure |
---|---|---|---|
25 | 8.6 | 230 | 0.09 |
30 | 9.9 | 267 | 0.12 |
35 | 11.7 | 313 | 0.15 |
40 | 13.9 | 373 | 0.20 |
45 | 16.9 | 453 | 0.28 |
Inlet Temperature to the Card (°C) |
CFM | LFM | Static Pressure |
---|---|---|---|
25 | 9.5 | 256 | 0.11 |
30 | 11.1 | 297 | 0.14 |
35 | 13.0 | 350 | 0.18 |
40 | 15.6 | 418 | 0.24 |
45 | 18.9 | 509 | 0.34 |