Table 1. Comparison of AIE Generations
  AI Engine AIE-ML AIE-ML v2
Compute
Multipliers per Tile (non-exhaustive list)
  • 128 (INT8xINT8)
  • 8 (fp32)
  • 256 (INT8xINT8)
  • 128 (bfloat16)
  • 512 (INT8xINT8)
  • 256 (bfloat16, fp16)
  • 512 (fp8)
  • 512 (MX9)
  • 1024 (MX6)
Bandwidth to Local Memory
Load from data memory in same Tile 64 B/cycle 64 B/cycle 128 B/cycle
Load from data memory in neighboring Tiles 64 B/cycle 64 B/cycle 64 B/cycle from a single neighbor

128 B/cycle from two neighbors

Store 32 B/cycle 32 B/cycle 64 B/cycle
Cascade bandwidth 48 B/cycle 64 B/cycle 64 B/cycle
On-chip Data Memory
Per Compute Tile
  • 32 KB
  • 128 B/cycle
  • (8 x 16B banks)
  • 64 KB
  • 128 B/cycle
  • (8 x 16B banks)
  • 64 KB
  • 256 B/cycle
  • (8 x 32B banks)
Per Memory Tile No memory tiles
  • 512 KB
  • 256 B/cycle
  • (16 x 16B banks)
  • 512 KB
  • 256 B/cycle
  • (16 x 32B banks)
DMAs
Compute Tile
  • 2 MM2S
  • 2 S2MM
  • 2 MM2S
  • 2 S2MM
  • 2 MM2S
  • 2 S2MM
Memory Tile No memory tiles
  • 6 MM2S
  • 6 S2MM
  • 6 MM2S
  • 6 S2MM
Interface Tile
  • 2 MM2S
  • 2 S2MM
  • 2 MM2S
  • 2 S2MM
  • 2 MM2S
  • 2 S2MM
Stream Interconnect
  32b 32b 64b
Compute Tile
  • South to North: 6 (24 B/cycle)
  • North to South: 4 (16 B/cycle)
  • East to West: 4 (16 B/cycle)
  • West to East: 4 (16 B/cycle)
  • South to North: 6 (24 B/cycle)
  • North to South: 4 (16 B/cycle)
  • East to West: 4 (16 B/cycle)
  • West to East: 4 (16 B/cycle)
  • South to North: 6 (48 B/cycle)
  • North to South: 4 (32 B/cycle)
  • East to West: 4 (32 B/cycle)
  • West to East: 4 (32 B/cycle)
Memory Tile No memory tiles
  • South to North: 6 (24 B/cycle)
  • North to South: 4 (16 B/cycle)
  • East to West: 0
  • West to East: 0
  • South to North: 6 (48 B/cycle)
  • North to South: 4 (32 B/cycle)
  • East to West: 0
  • West to East: 0
Interface Tile
  • From South: 8 (32 B/cycle)
  • To South: 6 (24 B/cycle)
  • From North: 4 (16 B/cycle)
  • To North: 6 (24 B/cycle)
  • East to West: 4 (16 B/cycle)
  • West to East: 4 (16 B/cycle)
  • From South: 8 (32 B/cycle)
  • To South: 6 (24 B/cycle)
  • From North: 4 (16 B/cycle)
  • To North: 6 (24 B/cycle)
  • East to West: 4 (16 B/cycle)
  • West to East: 4 (16 B/cycle)
  • From South: 8 (64 B/cycle)
  • To South: 6 (48 B/cycle)
  • From North: 4 (32 B/cycle)
  • To North: 6 (48 B/cycle)
  • East to West: 4 (32 B/cycle)
  • West to East: 4 (32 B/cycle)
PL/Array Interface
  • From PL: 8 (64B/cycle @ PL clock)
  • To PL: 6 (48 B/cycle @ PL clock)
  • From PL: 8 (64B/cycle @ PL clock)
  • To PL: 6 (48 B/cycle @ PL clock)
  • From PL: 8 (64B/cycle @ PL clock)
  • To PL: 6 (48 B/cycle @ PL clock)
Includes Control Module?
  No No Yes