The prefix on the SWDT I/O signal names are mapped to the watchdog timer instances:
- LPD_SWDT for the RPU, located in the LPD subsystem (refer to SWDT0)
- FPD_SWDT for the APU, located in the FPD subsystem (refer to SWDT1)
The I/O interface signals for the SWDT[0,1] are available on the PMC and LPD MIO pins as shown in the following table and in the tables in the MIO-at-a-Glance Tables section. The signals are described in the Signals to the Timer section.
Signal Name | MIO | EMIO | ||
---|---|---|---|---|
MIO-at-a-Glance Table | I/O | Signal Name | I/O | |
SWDTx_CLK |
CLK | I | I | |
SWDTx_RST |
RST | O | EMIOWDTRESET | O |
SWDTx_RST_PEND |
PEND | O | EMIOWDTRESETPENDING | O |
SWDTx_INT |
INT | O | EMIOWDTINTERRUPT | O |
SWDTx_GWS0 |
WS0 | O | EMIOGWDTWS | O |
SWDTx_GWS1 |
GWS1 |
O | EMIOGWDTWS | O |
SWDTx_ERROR |
- | - | EMIOWDTERRTOPL | O |