The base time period is programmed by selecting the reference clock and the number of clock periods to include in the time base. The registers for channel 0 are:

  • Select base clock: CLKMON0_CTRL [BASECLK_SEL]
  • Program cycles per base time period: CLKMON0_BASE [CLK_CYCLES]

The REF_CLK is typically 33 MHz, but can be higher or lower. The PMC_IRO_CLK is typically 400 MHz for high and mid voltage speed grade devices or typically 320 MHz for low voltage speed grade devices.. These are independent clocks. The frequency range for REF_CLK and the trimmed frequency of the PMC_IRO_CLK are listed in the DC/AC data sheet.

Figure 1. ClkMon Base Time Period