In the Import XPE wizard, provide the path to the .xpe file you want to import and click OK.
The following screen is displayed.
The following table shows a comparison between power estimates in compilation versus simulation flows in the PDM.
| Component | Static (W) | Dynamic (W) | Total (W) | Static (W) | Dynamic (W) | Total (W) |
| Import Compilation Flow | Import Simulation Flow | |||||
| PL | 7.5 | 1.9 | 9.4 | 7.5 | 1.9 | 9.4 |
| AI Engine | 4.8 | 4.3 | 9.1 | 4.8 | 1.7 | 6.5 |
| PS+PMC | 0.2 | 1.3 | 1.5 | 0.2 | 1.3 | 1.5 |
| Everything else (NoC, DDRMC, GTY, etc) | 1.1 | 8.7 | 9.8 | 1.1 | 8.7 | 9.8 |
| Total (W) | 13.6 | 16.3 | 29.9 | 13.6 | 13.7 | 27.3 |