Power is measured using the Vivado tool. Use the following steps to retrieve this information from the Vivado project.
Open the Vivado based power.xpe in PDM.
Click the dsp tab and view the power consumed for the 32 x 32 x 32 design.
The following table provides a summary of power utilization:
GeMM Configuration |
Dynamic Power (W) |
|---|---|
32x32x32 |
7.469 |
64x64x64 |
8.659 |
128x128x128 |
8.665 |
256x256x256 |
8.682 |
512x512x512 |
8.538 |
1024x1024x1024 |
8.682 |