Channelizer Requirements - 2025.1 English - XD100

Vitis Tutorials: AI Engine Development (XD100)

Document ID
XD100
Release Date
2025-08-25
Version
2025.1 English

The following table shows the system requirements for the polyphase channelizer. The sampling rate is 2 GSPS. The design supports M=4096 channels with each channel supporting 2G / 4096 = 488.28125 KHz of bandwidth. The filterbank used by the channelizer uses K=36 taps per phase, leading to a total of 4096 x 36 = 147456 taps overall.

Parameter Value Units
Sampling Rate (Fs) 2 GSPS
# of Channels (M) 4096 channels
Channel Bandwidth 488.28125 KHz
# of taps per phase (K) 36 n/a
Input datatype cint16 n/a
Output datatype cint32 n/a
Filterbank coefficient type int32 n/a
FFT twiddle type cint16 n/a